RPBHB Series Intumescent Pad
For Electrical Flush Boxes & Washing Machine Inlet Boxes

Application:
Installed inside fire-resistant flush boxes or washing machine inlet boxes on one or both sides of compartment walls.

Material: Intumescent compound
Color: Black, smooth surface
Expansion Ratio: 20–30 times

Features:
Fire, heat, and smoke sealing
Waterproof and clean finish
Easy to install – no adhesive needed
RoHS compliant
Suitable for damp areas (e.g., laundry rooms)

Send Inquiry

What are the benefits of using RPBHB Series Intumescent Pad?

Thickness

Width

Length

8mm

46 mm

48 mm

6mm

45mm

75mm

3mm

100mm

100mm

8mm

32mm

64mm

Any other size can be customized

  1. RPBHB Series Intumescent Pad for Electrical Flush Boxes & Washing Machine Inlet Boxes

    Application:
    Designed for back-to-back installation inside fire-resistant electrical flush boxes and washing machine inlet boxes within compartment walls (single or both sides)

    Material: Intumescent compound
    Color: Black with a smooth surface
    Expansion Ratio: 20–30 times

    Features:

    High Expansion Performance
    Expands rapidly when exposed to heat, forming an effective fire and smoke seal.

    Waterproof Surface
    Moisture-resistant material ensures long-term reliability, even in damp environments like laundry rooms.

    Smooth, Clean Appearance
    Neat finish with no additional surface treatment required.

    Quick and Easy Installation
    Flexible pad is easy to insert—no adhesive or special tools needed.

    Versatile Use
    Suitable for both electrical flush boxes and washing machine inlet boxes, enhancing fire safety in multiple wall-mounted installations.

    Environmental Compliance
    RoHS-compliant, non-toxic, and environmentally friendly.

RPBHB series
intumescent pad for washing machine water inlet boxes

The fireproof gasket for the washing machine water inlet box is a passive fireproof sealing component specially used in the water pipe interface area of ​​the washing machine. It is designed to automatically expand when a fire occurs and block the fire from spreading through the water pipe penetration to the back of the wall, effectively improving the fire safety level of household appliances.

Automatic expansion seal: The gasket is embedded with fireproof expansion materials (such as expanded graphite or sodium silicate), which expands rapidly at high temperatures of 150–200°C to fill the gap between the water pipe and the wall

Compact structure: It is suitable for the standard size of the washing machine water inlet box, easy to install, and does not affect the normal water circulation;
Fireproof and heat insulation: After expansion, a carbon layer/foam structure is formed to prevent the penetration of flames, heat and smoke, and delay the spread of fire
Send Inquiry

Installation Examples

Get Your Custom Intumescent Fire Door Strips

RESSA is a trusted supplier of full range of intumescent fire door strips, with years of experience in creating high-quality fire protection solutions. It specializes in manufacturing high-quality custom fire door seals and gaskets to cover various need of customers. Here are your custom selections:

Get A free quote

Features that Make Our Intumescent Fire Door Strips Unique

expanding RESSA RPB Series Intumesent Fire Strips

Advanced Expansion Technology

RESSA intumescent fire door strips are engineered with a proprietary heat-activated expansion process that ensures rapid and uniform swelling of seals in fire, creating an impenetrable barrier against fire and smoke.

Superior Self Adhesive Performance

Surface mounted fire door strips equipped with industrial-grade adhesive, our strips self adhere firmly to a variety of surfaces, ensuring a long-lasting seal that won’t degrade over time or under extreme temperatures.

intumescent -RESSA RPB Series Fire door strips

Multi-Functional Sealing Performance

Beyond fire door insulation, some our intumescent fire door strips also offer excellent waterproof property, smoke prevent property, acoustic insulation and thermal properties, adding additional value to the installation.

BS476 Test RESSA RPB Series Intumesent Fire Strips

Tested Prooved and Certified Quality

Our products pass the testing of fire doors integrity and insulation test according to the BS476 test standard and have received certification from recognized safety standards organizations, assuring their effectiveness and reliability.

Manufacturing Process of Intumescent Fire Door Strips

  1. Raw Material Preparation: Gather materials including different kinds of fireproof intumescent materials, self adhesive, additives… ensure material expand to meet quality standards of fire doors requirement.
  2. Mixing: Mix the raw materials according to the formula and prepare them under specific temperature and humidity conditions. This may involve blending the expanding materials with other additives to achieve the desired physical and chemical properties.
  3. Extrusion or Calendering: Use an extrusion machine or pressing machine or inserting machine to shape the mixed intumescent materials, forming the initial shape of the intermittent strips.
  4. Cutting and Shaping: Cut the intermission strips to the specific dimensions and shapes. Precise molding may be achieved using molds or cutting tools.
  5. Quality Testing: Perform quality tests, including dimension checks, expansion performance, fire resistance, etc.for intumescent gasket.
  6. Packaging and Dispatch:Package the qualified intumescent strips and prepare them for dispatch to the market.
GET A FREE QUOTE
Intumescent strips production process

Our Certificates in Intumescent Fire Door Strips

RESSA Test certificate (4)
RESSA Test certificate (5)
RESSA Test certificate (6)
RESSA Test certificate (1)

Ready to Get the Perfect Fire Door Strips?

Contact Us to Get A Free Consultation

Fire Door Strips FAQs

Fire Door Strips are specialized seals installed on fire doors to prevent the passage of smoke, flames, and toxic gases during a fire, enhancing the door’s ability to compartmentalize and contain the spread of fire.

Over-painting of fire door strips should not compromise performance in a fire situation – however, do not suggest paint over fire door strips as this will certainly compromise the sealing containment performance and use life. If the intumescent strips on fire doors has already been painted over, you will need to replace it. Our seals are available in a range of colours, plus woodgrain and metallic finishes, so over-painting should not be necessary.

In the event of a serious fire, fire doors are one of the most important components in ensuring safe exit, containing the fire and saving lives. But they can be rendered useless by not using the correct components including intumescent strip. Gaps around the four sides of a fire door leaf are essential, it is the only way the door can open and close. But these gaps create a point of weakness, where fire can take hold and destroy the door, and toxic and smoke can pass through. RESSA intumescent strip works by sealing around the edges and gaps of a fire door and door frames in the event of a fire.

In essence, all intumescent do the same job, but not necessarily in the same way. You’ll need to know which specifications you require; consult our technical team to discuss this area in depth at [email protected].

Yes, RPB Series flexible fire door strips are suitable for both new builds and for retrofitting into existing structures, providing an effective fire-stopping solution. The intallation method is very easy by self-adhesive.

Blogs About Fire Door Strips

Contact Us